m302 p1. @jfavre said in Extruder motor not working. m302 p1

 
@jfavre said in Extruder motor not workingm302 p1 M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle

Send G1 E100 F200 to extrude 100mm of filament. 4 and an arduino mega 2560. Reply Quote. Only users with topic management privileges can see it. You could also put those commands in a normal text file with the file ending ". Disable any mesh bed leveling procedures in. Serial No. retraction temperature 90. If you want to test your extruder, you can disable cold extrusion prevention using M302: M302 P1. 5 (2022-11-30 19:41:16) running on Duet 3 Mini5plus WiFi (SBC mode)M302 P1 ; cold extrude: G92 × 0 Y0 Z0 ; set current position to {X = 0,Y = 0,Z = 0} G92 E0 ;zero the extruded length: G1 F200 E0. M302 works fine in a starting script or sent via console. G1 F900 ; set the feed-rate // Starting the print with Layer 0 ;Layer count: 2. @dc42 That doesn't seem to work. Large delta printer [ miscsolutions. Does the motor turn? If yes, then probably it’s not having enough power to push the filament through the nozzle. 8Hz when using P4. g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. 15mm Nozzle (Pink)The punch slide unit is driven by the punch shift motor (M302). 23". The extruder can't always move as fast s the other axes, that's why my examples to move E use a slower speed (F value). 0. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. Set the temperature (and enable) using. A well-grippable 3d-printable chess set is also included. The config changes were correct. M302. the X motor connector. But if you want to extrude cold, now you know how. 1 Reply Last reply Reply Quote 0. Re-enable with. I have almost everything working: Temp sensors All the axis drives including 4-Z steppers. M302 by itself displays the current cold extrusion status (RepRapFirmware). 0024. @agent0810 said in Homing advice: the z is at 0 at the top, so it cant go lower right? shouldnt it home at 300 something? im having issues moveing the bed. Anytime I extrude a certain length of filament, the extruder retracts the same length it seems. g: T0 ; select tool 0. elvoron mr approval drawing & signature required. Cannot get extruder motor to respond. Home page Shop all products. ; Configuration file for Duet WiFi (firmware version 2. 168. 0C, min. I have a setup similar to the ANET A8. droftarts administrators @flyscha last edited by . G28: home all axes. I use duet wifi version 1. HI again, what I'm doing wrong, the extruder buttons in DWC won't be gray, its grayed out. send T0), and enable cold extrusion with M302 P1. How would I know to send a T0 and then M302 P1 to test the extruder? Quote dc42 Make sure you have a tool selected (e. Both versions work on Duet 2. This will restore the last configured Revo insert on the next restart of the firmware. Hello. wordpress. is not colored in WebControl as in the example screenshots i saw. Only users with topic management privileges can see it. M302 P0 ; disable cold extrusion M291 P"Filament autoload complete!" S0 T3 ; display message . The G Code already asks for cold extrusion M302 P1… I think the problem if it is all connected up as it should be is in the Config file assuming the Extruder logic is OK and hasn’t been damaged by having a motor output. droftarts administrators @flyscha last edited by . Edit. Recently i have been testing the clay extruder connected to the Driver0 on Duet 3 Mainboard 6HC. Wood filament wont extrude / print below 200deg. the X motor. It works perfectly fine on RRF2 though. The extrusion amount of the first layer is extremely low, but the other layers are fine. the 0, 1,2 drivers still work fine. Click to Enlarge. Duet Web Control makes it easy to upload, edit and create new macros. 0C. Bug. Then reduce the distance, and stop just before the filament disappears into the hot end. droftarts administrators @flyscha last edited by . 0. 36°C/sec measured -0. : M302 Just got the extruder motor to work with G1 E1 F100 andG1 E-1 F100. This was done on Marlin 2. M302 P0. and Terra makes the best looking meshes by far. Now all the other axis are moving as supposed but the extruder ones are not. La commande G-code M302 P1 permet l'extrusion a froid. A typical piece of GCode sent to a machine running RepRapFirmware might look like this (The meaning of these codes (and more) is. 0. M302 P0. 1 active and standby temperatures to 0C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C $\begingroup$ That fix, sending M302 P1 (the P1 is important) and then M500 can be done in any program that can communicate directly with the printer. M570 S180 ; allow it 180 seconds before gving a heating warning and test hotends wont be tuned. Duet Web Control makes it easy to upload, edit and create new macros. And now even Col Extrusion M302 P1 is generating errors. 0. Make anothe mark on the filament right where it leaves the fitting. M302 ; report current cold extrusion state M302 P0 ; enable cold extrusion checking M302 P1 ; disable cold extrusion checking M302 S0 ; always allow extrusion (disable checking) M302 S170 ; only allow extrusion above 170 M302 S170 P1 ; set min extrude temp to 170 but leave disabled. The endstop is connected and is working, the wir. So no need to use M302. PROMEGA I have installed a BL Touch clone and it works with the direct commands. 8 is far too low for two reasons: 1. I reduced. 00 and cannot get the stepper motors of the extruders to work. org ] Reply Quote. g: 1. Other possible causes are a bad stepper motor or cable. This topic has been deleted. These are commands that one may enter into the OctoPrint terminal tab. the X motor. @Phaedrux How would I combine the two M558 linesFilament is free for manual feeding" S2 ; blocking, but blocks DWC too M25 ; Pause (not like I wish to pause) G1 W{param. g ; go to purge bucket. In that case, you might use M302 S65 or similar to drop the MIN_TEMP. config. Dear all i have 4 heaters, when i try to heat all of them at same time, it automatically goes to standby mode, what will be reason? when i individually heat them it works fine. @agent0810 said in Homing advice: i was able to. M106 P0 S0 H-1 ; set fan 0 value. Here is a handy list of g-code commands [ reprap. Looking for a way that is super native, standalone and low end way to get it to do that without using high level programming architecture, such as not using software that is running on python or what not. M302 P1 ; enable cold extrusion M201 E1000 ; reduce extruder acceleration M915 P3 S10 F0 R0 ; set stall detection threshold M913 E100 ; set extruder motor to reduced % current M83 ; relative extrusion G1 S1 E800 F3600 ; move fast 500mm of filament M913 E100 ; set extruder motor to full current M302 P0 ; disable cold extrusion G1 E50 F300. 3 ; Filter. yello3d. - Only upon M302 P1 to enable cold extrusion (if not heated) through pronterface, can I use the "Extrude" or "Reverse" button on the UI. Other possible causes are a bad stepper motor or cable. g. Other possible causes are a bad stepper motor or cable. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. -> no reaction at all - even after "M302 P1" What is working: Homing. M302 P1 disables the cold extrude safety. g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. Speaking of which. Zuletzt am 03. 7. Chances are you are getting a message saying either "Attempt to extrude with no tool selected" or "Tool n was not driven because its heaters were not hot enough". 1 Reply Last reply Reply Quote 0. . I just wondered if there was a way of "embedding" it in the config files so that it runs by default. Sending T0 initiates the heater and then faults out. All models of the M1 carbine family (including the M2 and M3 carbines) fired a . 7. If calibrating cold, run M302 P1 (allows cold extrusion) If calibrating hot, heat your hotend to printing temp. M302 Allow Cold Extrudes [Pnn/Snn/Rmm] Allow cold extrude, set min extrude & retract temps M302 P1 ; Allow cold extrusion M552 Set IP, enable/disable network in[Pnn / Snn/ Rnn] P(IPV4 address) S(0|1 enable|disable, M552 S1 P192. The code sends commands to an Octoprint instance. 0 Y0. 16AFDVC1 -. Note to Users This Service Manual is constructed using a system of issue letters (alphas. 1 OS hope it might work on it. M302 P1 ; Allow cold extrusion Just enter the above code from your host software (pronterface or repitear) and you should be good to test the paste extruder. M302 P1; Axis Limits M208 X-50 Y0 Z0 U0 S1 ; set axis minima M208 X210 Y220 U260 Z200 S0 ; set axis maxima ; Endstops M574 X1 S1 P"io0" ; configure switch-type (e. Well broadly speaking I think this is the basis for the new UM3 bed probing, the probe presses on the glass which triggers a capacitative sensor underneath. For firmware versions 1. Recently i have been testing the clay extruder connected to the Driver0 on Duet 3 Mainboard 6HC. P1: Stroke: CT/CTA should also be considered; Appendicitis: MRI rarely indicated. microswitch) endstop. M116 P0 ; wait for heating up. Then select the plugin ZIP file and confirm the following steps. M302 P0. 30 caliber carbine cartridge from 15-round and 30-round detachable box magazines. Suppose they are, in fact, 105mm apart. This code and 3D models allow you to make a chess robot out of your 3D printer. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. Currently the paneldue displays the thermistor readings appropriately for thermistor 1 and 2 of the Duex5, which leads me to believe that the Duex5 is wired correctly. . 1 Reply Last reply Reply Quote 0. You will have to preheat the hotend first before moving E or you can try sending the M302 P1 Gcode via the terminal in pronterface to allow cold extrusion. I have been clicking the 'retract' and 'extrude' button multiple times to push the plunger down to the correct position and to retract the plunger from the bottom of the cylinder after the print. 0C. M302 P1 Now advance the filament using the jog buttons on the Manual Control tab, until it reaches the top of the heatsink. P1: Acute abdominal pain (e. short Signal and +3. droftarts administrators @flyscha last edited by . Items 1 - 36 of 42. +Z should move the bed down. 4 S240 M307If calibrating cold, run M302 P1 (allows cold extrusion) If calibrating hot, heat your hotend to printing temp. M302 P1 ; Allow cold extrusion M82 ; use absolute distances for extrusion G92 E0 ; Reset Extruder G1 E-430 F3600 ; retract 430 mm M302 P0 ; Disable cold extrusion T-1 P0 ; Deselect all tools without running any tool change macros. The prototype was outsourced to Oshpark. Many thanks! ;FLAVOR:Marlin ;TIME:40 ;Filament used: 0. g. Crypto@gloomyandy are these values incorrect?; Tools M563 P0 S"volcano" D0 H1 F0 ; define tool 0 G10 P0 X0 Y0 Z0 ; set tool 0 axis offsetsExtruder SKR2 not spinning. microswitch) endstop. -> no reaction at all - even after "M302 P1" What is working: Homing. And, for swapping purposes, don't forget the extruder motor/cable/port. yello3d. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. . 3 or later ;M17 A B G92 A0 B0 G1 A0 B0 F20000. retraction temperature 90. M302_P1_COLD_E. . M302 P1 allows cold extrusion (RepRapFirmware). Don't disable the thermal runaway protection. 5 fans I have it doing all zeroing and even bed tramming! Awesome to see it tram a skewed-. Macros also allow for naming gcodes with easier to remember names. How bout if you heat up the hotend to 180?How bout if you heat up the hotend to 180?How bout if you heat up the hotend to 180?M302 P1 ; Allow cold extrusion Just enter the above code from your host software (pronterface or repitear) and you should be good to test the paste extruder. However, Slic3r inserts this code after the first Z-lift which is befo. @patel said in how to change homing sequence: M3D promega There's a full guide to this on M3D's Promega support pages. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. ; pre 3. This manual describes the machines of the INTEGREX e-series, INTEGREX i-series, and VORTEX i-series. Just need to find settings for Slice Engineering 300c thermistor, the temp reading slightly higher than actual measured with an TC thermometer. G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Green - filament present. Heating Bed manually by G-Code. M117 Let's make some filament!;Turn on fan;M106. Direct drive: Remove your nozzle, hotend, or extruder. 0. When tfreeN is called, filament is retracted above the y-splitter. T0, you need to either heat up that tool, or enable cold extrusion by sending M302 P1. 455513e-8@gloomyandy are these values incorrect?; Tools M563 P0 S"volcano" D0 H1 F0 ; define tool 0 G10 P0 X0 Y0 Z0 ; set tool 0 axis offsetsBusiness, Economics, and Finance. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. J'y connais pas grand chose dans les imprimantes 3D, moi jusque là, ça fonctionnais donc je ne m’intéressai pas trop au reste, mais là, je suis bien obligé, et donc je ne sais pas faire la commande G-code que tu m'indique, ou faire ça dans Repetier-Host ?M302 P1 ; cold extrude. Zuletzt am 03. Heater 1 fault: temperature rising too slowly: expected 2. 9 mm of feed stock: G92 E0 ;zero the extruded length again: G1 F900 ; set the feed-rate // Starting the print with Layer 0;Layer count: 1;LAYER:0: M107Preheat the hot end, if desired (or send M302 P1 if you intend to use the macro when the hot end is cold) Use M913 Ennn to reduce the motor current, if necessary (see #1 above) Use M83 to select relative extruder motion, in case the macro is. ; Tool definitions M563 P0 D0 H1 ; Define tool 0 M302 P1 ; Allow Cold extrudes; Thermistors M305 P0 T100000 B3950 R2200 H30 L0 M305 P1 T100000 B3950 R2200 H30 L0 M305 P2 T100000 B3950 R2200 H30 L0. In order to move the extruder, do I need set the temperature control input for the extruder heater? I have setup multiple tools that share a heater and have dedicated extruder drives. 0C. Tried setting up the extruder on drive 4 then on drive 3. M569 P1 S0 ; physical drive 1 goes forwards using default driver timings M569 P2 S1 ; physical drive 2 goes forwards using default driver timings. In order to report the current status, run. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTPM302 P1;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. extrusion temperature 160. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. 0. droftarts administrators @flyscha last edited by . 3 E40 ; set drive mapping. Only users with topic management privileges can see it. 1) into the DWC console. wordpress. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTP M586 P1 S0 ; Disable FTP M586 P2 S0 ; Disable. Chances are you are getting a message saying either "Attempt to extrude with no tool selected" or "Tool n was not driven because its heaters were not hot enough". I probed the STEP output with an oscilloscope and the pulses are there and the pulse length is fine. 00" standard bore "competition" gasket for cast iron or aluminum cylinder heads on 302 and 351W production blocks. If calibrating cold: Bowden: Disconnect the bowden tube from your extruder. This document describes the commands that Klipper supports. M950 F1 C"fan1" Q500 ; create fan 1 on pin fan1 and set its frequency. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. I would be very gratefull for any help. Heating Bed manually by G-Code. M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle. Saved searches Use saved searches to filter your results more quicklyM569 P1 S0 ; physical drive 1 goes forwards using default driver timings M569 P2 S1 ; physical drive 2 goes forwards using default driver timings. This topic has been deleted. Example output if disabled: echo:Cold extrudes are disabled (min temp 170C) Example output if enabled:M581 P1 T2 S0 R0 ;define trigger for filament auto load triggers trigger2. . x) G92 A-1 B-1 ; Make Zrot & Tilt active G1 A0 B0 ; 3. Command "M302 P1" works properly. @droftarts OK, I wish I knew which of the changes finally mattered but I don't. When I try to run the extruder (for example G1 E1) I make sure to allow cold extrusion (M302 P1). Thanks. M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle. g. M302 P0 S170. This is the stuff I'm finishing for 2019, they are hairpins in two colors that I do with an advanced Pause script that allows me to Atomic plug the filament totally unmanned and waits for me until I go to change the color and click resume. Re: Extrude without a Hotend May 04, 2017 11:25PM. yello3d. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. M302 P1 ; allow cold extrusion. 0. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. So I attached a thermistor to the board just to "fool" the board into thinking there was an active heater but then I get temperature errors. Hi, Bringing up my re-controlled Vivendo Troodon 400 with a 6HC and 3HC. ; pre 3. G-Code commands¶@jfavre said in Extruder motor not working. 0 C199. 1 Reply Last reply Reply Quote 0 droftarts administrators @flyscha last edited by M302 P1 ; allow cold extrude M302 S0 R0 ; allow cold extrude;M563 P1 P3 S"filament" D1 H1 H3 F4 ; define tool 1;G10 P1 X0 Y0 Z0 ; set tool 1 axis offsets;G10 P1 R0 S0 ; set initial tool 1. yello3d. The printer functions and works as a normal syringe printer and is compatible with the Lulzbot Cura slicer software. 0 S1 ; physical drive 1. These are commands that one may enter into the OctoPrint terminal tab. 1 Reply Last reply Reply Quote 0. M808. So please send T0 and M302 P1 and then see if you can send G1 E1 F100 to make. g ; Unload to above y-splitter. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. If you want to test your extruder, you can disable cold extrusion prevention using M302: M302 P1. Without inserting the wire I tried to make a print and the extruder works. 9mm of feed stock. However, some firmware distributions might explicitly prevent these two commands of turning off the check. 0. When I print using the code below (it is longer, but I do not know where to put attachments), I can see that the extruder-gear is jerking, as if it tries to do tiny retractions between every little movement. G1 E15 F500 ; load filament insi de the gears. approved - date, name. 9 Windows 10 I am using a macro in reprapFirmware to pause the print for a certain length of time after evey layer. For coding you should add M302 P0 to your ending gcode to re-enable the safety at the end of the file. Currently the paneldue displays the thermistor readings appropriately for thermistor 1 and 2 of the Duex5, which leads me to believe that the Duex5 is wired correctly. I have to turn the power off and on to reset it. Only users with topic management privileges can see it. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. This is by far the only way I am able to see that the steppers can actually work through the board. 1 Reply Last reply Reply Quote 0 M302 ; report current cold extrusion state M302 P0 ; enable cold extrusion checking M302 P1 ; disable cold extrusion checking M302 S0 ; always allow extrusion (disable checking) M302 S170 ; only allow extrusion above 170 M302 S170 P1 ; set min extrude temp to 170 but leave disabled I've processed a lot of the same flights in Terra, Pix4D, and Agisoft. Duet 3 mini 5+ installed in a Sidewinder x1 v1. g. 8 is far too low for two reasons: 1. DWC / Duet will sit and wait until the +3. M302: Allow cold extrudes Examples M302 M302 P1 This tells the printer to allow movement of the extruder motor, when the hotend is not at printing temperature. M950 F0 C"fan0" Q500 ; create fan 0 on pin fan0 and set its frequency. g. I can put a dummy value on the T0 to verify the good functioning of the Titan. 499. 1. Now with Marilin 2. 4. g. . g. 16 07:24. With steps/mm so low you will get nothing like enough torque out of your motor to extrude anything, unless it is a really huge motor. What is the trigger word to tell the firmware that we are starting a new layer? KulitorumHow bout if you heat up the hotend to 180?Hi *, I hope that somebody can help me here. g to make the process as painless as possible. M302 P0 disallows cold extrusion. . Ok i did the test you asked and did the commands thru the gcode console and with tool 0 on drive 0 selected when i give the G1 E20 F5 command i get a slight twitch on the motor shaft but the shaft spins freely with little to no resistance on the shaft i switched the motor cable to the drive 1 and set my config_g to use tool 0 drive one and with tool 0. 155 5. the X motor. 00°C/sec. It may have allowed the extruder to run on the 6HC but I'm thinking the DWC may have still been blocking the sending of any extrude or retraction presses while it looked only at the temperature before enabling the sowtware buttons. M302 P1 ;allows cold extrusion with RepRap, otherwise "M302" alone works T0 ;selects tool0;M563 S1 ;allows for tool nomenclature compatibility between Slic3r and RepRap (Tools 0&1 vs Toos 1&2) I don't even want to do homing yet because my endstops are still screwed up, fortunately for my purposes I don't actually require them to work to. However, a steps/mm value of 5. M302 P1;G92 E0. yello3d. M83 ; set extruder to relative mode echo "Start" G1 E60 F150 ; Extrude 60mm at 2. 4 card. M302 P1 which just disables temperature checking. I have some fillamentum wood filament, according to the website print temperature: 170 - 185 °C, however nothing prints within this range. 2. M569 P0 S1 ; Reverse the X motor M563 P0 D0 H1 ; Define tool 1 G10 P0 S0 R0 ; Set tool 1 operating and standby temperatures M563 P1 D1 H2 ; Define tool 2 (un-comment this for dual nozzle machines) G10 P1 X19 S0 R0 ; Set tool 2 operating and standby temperatures (un-comment this for dual nozzle machines) M92 E447:447 ; Set. If you are using the web interface, go to the Gcode. CryptoM302 P1 ; enable cold extrusion G4 S1 ; wait for one second G1 E15 F500 ; load filament inside the gears. I thought I was having problems outputting STEP and DIR to the G320x, but actually it was a current issue in 3. My config file is in experimental stages, but the Cartesian axis worked. You could do it it by turning off the safety limit which prevents cold extrusion. value=1 ; draw back manual feeded filament out of sensor G1 E-1 F500 G1 E1 F500 ;. After I have executed the M302 S1 command, the extruder moves a few steps in one direction and then stops. . The M2 Carbine rifle is a fully automatic version of the M1A1. gco M24 Start/resume SD print M25 Pause SD print M26 [S(Bytes(s)/Pnn] Set SD position. The macro folder can divided into sub directories to more easily organise your macros by type. Don't expect G0 or G1 to make it move, when not homed. Technical Explanation 1. Wood filament wont extrude / print below 200deg. G92 X0 Y0 Z0 ; set current position to {X=0,Y=0,Z=0} G92 E0 ;zero the extruded length. If calibrating cold: Bowden: Disconnect the bowden tube from your extruder. 5mm/sec echo "Done" M82 ; set extruder to abs mode 1 Reply Last reply Reply Quote 0M574 Y1 S1 P"!P1. Tools; M563 P1 S"Clay" D0 ; Define tool 1 M563 P2 S"plastic" D1 H2 ; Define tool 2 G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets Some common uses…. Trying to figure out why I can't run my extruder. I updated webcontrol and firmware several times without error, but no change. Last edit at 01/11/2023 01:58AM by Dust. Last edit at 01/11/2023 01:58AM by Dust. In order to report the current status, run. If calibrating cold, run M302 P1 (allows cold extrusion) If calibrating hot, heat your hotend to printing temp. For example you can create a Macro for "Allow Cold Extrude" to call M302 P1. This topic has been deleted. For coding you should add M302 P0 to your ending gcode to re-enable the safety at the end of the file. ) You can feed filament at 800mm/m (web interface max speed is 240mm/m), at 100mm at a time, until the filament is near the nozzle. Last edit at 01/11/2023 01:58AM by Dust. Send T0 before you try to extrude. g. Hi I am building a machine that is not a 3D printer but as I have liked a lot Duets for years now I decided to use one as a controller in this project too. I am at a loss for next step. 9. On Duet 3 if I send "M302P1" from the GCode console it returns "Error: Bad command". Chances are you are getting a message saying either "Attempt to extrude with no tool selected" or "Tool n was not driven because its heaters were not hot enough". Hi all, It turned out to be the end-stops micro switches causing the board to lose connection. Reply Quote. How can I make reprap firmware print without any heater or temperature sensors? Does it have a fake heater that I can make always return 200c or something to make the firmware extrude with a cold extruder, or even wi. Once satisfied the extruder drive is working, re-enable cold extrusion prevention using the following command: M302 P0 Reset the Active temperature for Heater 1 back to 190C. But if I use g28 to home the axis, it then will not work. Slic3r 1. I used to use "Pronterface" for that. Re: How can I move E steppers? January 11, 2023 02:36AMM302 P1 ; disable cold extrusion checking And yes each extruder is a tool T0 G1 E20 ; move current extruder 20mm T1 G1 E20 T2 G1 E20 Edited 2 time(s). What am I doing wrong? Thanks in advanceM302: Allow cold extrudes Examples M302 M302 P1 This tells the printer to allow movement of the extruder motor, when the hotend is not at printing temperature. Large delta printer [miscsolutions. This topic has been deleted. I tried webcontrol 1. M302 P1 ; Allow cold extrusion M82 ; use absolute distances for extrusion G92 E0 ; Reset Extruder G1 E-430 F3600 ; retract 430 mm M302 P0 ; Disable cold extrusion T-1 P0 ; Deselect all tools without running any tool change macros. droftarts administrators @flyscha last edited by . See: Promega SupportBusiness, Economics, and Finance. Other possible causes are a bad stepper motor or cable. When setting my Anet A8 printer at that temp, the extruder motor doesn't turn by…Beat me to it! If the current tool doesn't have any heaters assigned to it, extrusion is allowed always. 1 Z0. If you are using the web interface, go to the Gcode. Viko. M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle. Then try to extrude 5mm from Pronterface UI, there’s a button for it under the move. 5 (2022-11-30 19:41:16) running on Duet 3 Mini5plus WiFi (SBC mode)You need to edit homeall. Orange - unload button is pressed (only when filament is present) Please note the filament sensing button used here is not a standard TACT switch. X moves almost free, lets say as much as you can tell with the belt installed without the steppers. G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. On the X and Y we are using iHSS57-36-10 closed loop. This topic has been deleted. "M302 P1" tells the firmware it's ok to extrude though the hotend is cold. The commands I gave it was: T0 ; just to be sure M302 P1 ; I think it wM302 P1 ; allow cold extrusion. 1 active and standby temperatures to 0C. . M302 P1 (This will revert the next time you reset or power off the Duet, or you can send ‘M302 P0’. one immediately before X). Put this as first line of your custom gcode. g-code M302 P1; commonly used with syringe extrusion-based heads: Extruder temperature: g-code M104 S < Temperature >; 20 − 250 °C: Bed temperature: g-code M190 S < Temperature >; 20 − 150 °C: Extruder calibration: Firmware default: Uses the calibration defined in the 3D printer firmware: Steps per millimeter for the extruder a:. @fcwilt said in Duet 3 Extruder control disabled: Just to be sure turn the bed heat on along with the extruder heat and see if that changes anything. : till no luck with Extrusion Control jogging buttons. Extrude a small amount to ensure that your extruder motor is on and holding. 00 and cannot get the stepper motors of the extruders to work.